24 Vdc:
Whenconnectingtheintercomto24Vdc,eitherthepositive(+)supplyconductormustbefusedat
thesourcewitha1/2Afuseorapower-limitedpowersourcemustbeused.
TheAD-28X-MViscapableofsendingDCpowertoanotherunitwhichismountedinaremote
locationwithoutlocalpower.24Vdcisavailablefrompins4and5oftheterminalblock.Itcanbe
run along with the signal lines to an intercom in a remote location. Only one unit should share the
power supply of another unit in any installation.
NOTE
Connectpositive(+)supplyconductortopin#4ofterminalblock.Connectnegative(-)supply
connectortopin#5ofterminalblock.
Figure7inthewiringdiagramssectionshowshowtwointercomscanbehookedupifnoremote
power is available.
SURGE PROTECTION:
MetalOxideVaristor(MOV)devicesareusedtoprotecttheaudiolinesandtheremotecontrol
line. The intercom must have Earth Ground terminated to it to ensure surge protection.
TheoutputamplieroftheAD-28X-MVoffersfullshortcircuitprotectionandoverheatprotec‑
tion.
MODEL AD-28X-MV SPECIFICATIONS
OperatingVoltage 24Vdc,120Vacand240Vac50/60Hz
CurrentDraw Voltage Operating Standby
24Vdc 260mA 62mA
120Vac 163mA 70mA
240Vac 82mA 35mA
AmplierSpecications
FrequencyResponse(-6dB) 150Hzto12kHz
Input Impedance 3400 ohms
Max.OutputVoltage
Sine Wave:
UnbalancedOutput 7.5Vrms
SquareWave:
UnbalancedOutput 9.5Vrms
SpeakerRating 30watts
SpeakerImpedance 16ohms
TemperatureRangeforOrdinaryLocations –31°Fto+150°F(–35°Cto+66°C)
TemperatureRangeforHazardousLocations +41°Fto+149°F(+5°Cto+65°C)
FuseTypeGMC-1/2 1/2A,250V
CallButtonActuatedDryContactRating 500mAat125Vac
1.25A@24Vdc
Weight
Shipping 10lb,11oz
Net 9lb,4oz
HousingDimensions 6.5”(16.5cm)Wx9.88"(25.1cm)Hx
3.88"(9.9cm)D
ConduitEntrances Dual1/2"‑14 IPS
HousingMaterial Aluminum
Color Gray
-3-