Operating Principle:
• Whenonetalks,allintercomswillhear.
• Totalktootherstations,pressthetalk/listenswitchand
speakintothespeaker/microphone.Releasetalkswitchto
listen.
• PressingthecallbuttononremoteAorBprovidesa
contactclosureforanattention-gettingauxiliarysignaling
device, e.g. a strobe light.
NOTES:
1. Speaker/Microphone
2. Off/On/SpeakerVolumeControl
3. Listen/TalkSwitch
4. “Call”ToneSwitch
5. Customer-SuppliedAuxiliarySignalingDevice(e.g.,strobe
light)
Power Remote A Remote B
12-18VDC -- AD-26-3
120V50/60Hz AD-28X-MV AD-27-3
22-30VDC AD-28X-MV AD-56-3
240V50/60Hz AD-28X-MV AD-57-3
POWER CONNECTIONS (Remote B):
BLK +DCPower 12/24VModels
HOT 120/240VModels
WHT Common 12/24VModels
Neutral 120/240VModels
GRN EarthGround 120/240VModelsonly
Reminders:
• Beforeinstallingremoteintercoms,precautionsshouldbetakentopreventfeedbackbetweentwoormoreremotesincloseproximityandacousticallyreectiveareas.
• 16–20gaugelowvoltageaudiocable.Twistedpairnotrequired.
• Shieldedaudiocablenotrequiredunlessoperatinginhighelectromagneticelds.Groundoneendoftheshieldtoearthground.
• AudioandpowercablesarenotsuppliedwithAD-28X-MV.
• Thedrycontactscanbeusedtoswitchanauxiliaryaudibleorvisualsignalingdevicewhenthecallbuttonisdepressed.Themaximumratingsforthedrycontactsare0.5amps@125VACand1.25amps
@24VDC.Thismethodassuresacallisreceivedevenwhenthevolumeononeoftheintercomsisturnedallthewaydown.
11
290A4725-11
10
9
8
7
6
5
4
3
2
1
DRY CONTACT
FOR CALL
AUDIO (-)
AUDIO (+)
REMOTE
GROUND (-)
24VDC (+)
NEUTRAL
HOT
EARTH GROUND
AC
1K
1WATT
REMOTE A
1
3
2
4
BLK
AUDIO CABLE
TO OTHER
INTERCOMS
AUDIO
LINE
AUDIO
LINE
RED
WHT
-
POWER
+
POWER
GRN
REMOTE B
POWER
AUXILIARY
SIGNALING DEVICE
5
SEE POWER
CONNECTIONS
BLK
WHT
GRN
*
*
1
3
2
4
AUXILIARY
SIGNALING DEVICE
5
ATKINSON DYNAMICS