GRN
BLK
WHT
GRN 1
BLK 3
WHT 2
GRN 1
BLK 3
WHT 2
AUDIO
COMMON
CONTROL
290A3696
MASTER "A" MASTER "B" SLAVE
1
3
4
5
2
1
1
3
2
2
1K
1
WATT
SEE POWER
CONNECTIONS
BLK
WHT
GRN
*
*
BLK
WHT
GRN
*
BLK
WHT
GRN
*
Operating Principle:
• Masters normally listen to slave.
• Slave talks to master hands-free,
without having to press a talk switch.
• When any master talks, slave hears.
Other masters will hear.
• To talk into master, press talk switch
and speak into speaker/microphone.
Release talk switch to listen.
• To talk into hand-held microphone,
press talk switch on microphone and
speak into microphone element.
NOTES:
1. Speaker/Microphone
2. Off/On/Speaker volume control
3. Press-to-talk Switch
4. #137144 hand-held, noise cancelling
microphone
5. 3-conductor/16–22 gauge cable. Use
shielded cable in electrically noisy
areas. Ground one end of the shield to
“earth” ground. Ground chassis of DC
unit to ground.
Before installing remote intercoms, precautions should be taken to prevent feedback
between two or more remotes in close proximity and acoustically reflective areas.
Power Master A Master B Slave
12–18VDC AD-26C-7 AD-26C AD-26D
120V 50/60Hz AD-27C-7 AD-27C AD-27D
22-30VDC AD-56C-7 AD-56C AD-56D
240V 50/60Hz AD-57C-7 AD-57C AD-57D
POWER CONNECTIONS:
BLK +DC Power 12/24V Models
HOT 120/240V Models
WHT Common 12/24V Models
Neutral 120/240V Models
GRN Earth Ground 120/240V
Models only
4
-10-